Code/Variants |
Frame size |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
71 |
80 |
90 |
100 |
112 |
132 |
160 |
180 |
200 |
225 |
250 |
280 |
315 |
355 |
Administration |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+531 |
Sea freight packing |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+683 |
Prepared for ABB Ability Smart Sensor |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
+684 |
ABB Ability Smart sensor mounted |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
+865 |
One-year extension on standard warranty |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
Bearings and Lubrication |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+037 |
Roller bearing at D-end. |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
+041 |
Bearings regreasable via grease nipples. |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
○ |
○ |
○ |
+043 |
SPM compatible nipples for vibration measurement |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
+188 |
63-series bearing in D-end |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
- |
- |
- |
Branch standard designs |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+178 |
Stainless steel / acid proof bolts. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
Cooling system |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+068 |
Light alloy metal fan |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+183 |
Separate motor cooling (fan axial, N-end). |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
Earthing Bolt |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+067 |
External earthing bolt. |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
Heating elements |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+450 |
Heating element, 100-120 V |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+451 |
Heating element, 200 - 240 V |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
Marine |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+096 |
Fulfilling Lloyds Register of Shipping (LR) requirements, without certificate (non-essential duty only) |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+186 |
Fulfilling Det Norske Veritas (DNV) requirements, without certificate |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+492 |
Fulfilling Registro Italiano Navale (RINA) requirements, without certificate. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+496 |
Fulfilling Bureau Veritas (BV) requirements, without certificate (non-essential duty only) |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
- |
- |
- |
+675 |
Fulfilling American Bureau of Shipping (ABS) requirements, without certificate (non-essential duty only) |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
- |
- |
- |
Mounting arrangements |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+008 |
IM 2101 foot/flange mounted, IEC flange, from IM 1001 (B34 from B3). |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
- |
- |
- |
+009 |
IM 2001 foot/flange mounted, IEC flange, from IM 1001 (B35 from B3). |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+047 |
IM 3601 flange mounted, IEC flange, from IM 3001 (B14 from B5). |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
- |
- |
- |
+066 |
Modified for specified mounting position differing from IM B3 (1001), IM B5 (3001), B14 (3601), IM B35 (2001), IM B34 (2101) |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
Painting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+111 |
Painting system C3,durability Medium |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
+114 |
Special paint color, standard grade |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
Protection |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+005 |
Protective roof |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+072 |
Radial seal at D-end. Not possible for 2-pole , 280 and 315 frames |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+158 |
Degree of protection IP65. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+403 |
Degree of protection IP56. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+784 |
Gamma-seal at D-end. |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
- |
- |
- |
Rating & instruction plates |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+002 |
Restamping voltage, frequency and output, continuous duty. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+095 |
Restamping output (maintained voltage, frequency), intermittent duty. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+098 |
Stainless rating plate. |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
+135 |
Mounting of additional identification plate, stainless. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+159 |
Additional plate with text "Made in ...." |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+161 |
Additional rating plate delivered loose. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+163 |
Frequency converter rating plate. Rating data according to quotation. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
○ = Included as standard │ ● = Available as option │ - = Not applicable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Code/Variants |
Frame size |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
71 |
80 |
90 |
100 |
112 |
132 |
160 |
180 |
200 |
225 |
250 |
280 |
315 |
355 |
+181 |
Rating plate with ABB standard loadability values for VSD operation. Other auxiliaries for VSD operation to be selected as necessary. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+818 |
Restamping as generator |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
Standards and Regulations |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+331 |
IE1 motor not for sale for use in EU |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+540 |
China energy label |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+586 |
Fulfilling UK Conformity Assessment (UKCA) requirements. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+822 |
WIMES 3.03i6 Compliant Design for DOL operation |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
- |
- |
- |
+823 |
WIMES 3.03i6 Compliant Design for VSD operation |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
Stator winding temperature sensors |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+122 |
Bimetal detectors, break type (NCC), (3 in series), 150 °C, in stator winding |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+435 |
PTC - thermistors (3 in series), 130 °C, in stator winding |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+436 |
PTC - thermistors (3 in series), 150 ºC, in stator winding |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
+439 |
PTC - thermistors (2x3 in series), 150 °C, in stator winding |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+445 |
Pt100 2-wire in stator winding, 1 per phase |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
Terminal box |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+022 |
Cable entry LHS (seen from D-end). |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+230 |
Standard metal cable gland. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
+375 |
"Standard plastic cable gland (to close from Nov 1st)" |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
- |
- |
- |
+400 |
4 x 90 degr turnable terminal box. |
● |
● |
● |
● |
● |
● |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
+418 |
"Separate terminal box for auxiliaries, standard material. (to close from Nov 1st)" |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
- |
- |
- |
+447 |
Top mounted separate terminal box for monitoring equipment. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
+468 |
Cable entry from D-end. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
+731 |
"Two standard metal cable glands. (to close from Nov 1st)" |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
Testing |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+145 |
Type test report from a catalogue motor, 400 V 50 Hz. |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
- |
- |
- |
+148 |
Routine test report. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
Variable speed drives |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+472 |
1024 pulse tacho (L&L 861007455-1024). |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
- |
- |
- |
+473 |
2048 pulse tacho (L&L 861007455-2048). |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
- |
- |
- |
+701 |
Insulated bearing at N-end. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
+704 |
EMC cable entry. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
○ = Included as standard │ ● = Available as option │ - = Not applicable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|