Flumasys logo
En flag English Cs flag Čeština
M3BP Process performance cast iron motors
ABB Drives Low voltage motors IEC M3BP Process performance cast iron motors M3BP 450LB 2 - Process performance cast iron motor, class efficiency IE3, 2 poles, 900 kW, CENELEC

M3BP 450LB 2 - Process performance cast iron motor, class efficiency IE3, 2 poles, 900 kW, CENELEC

M3BP 450LB 2 - Process performance cast iron motor, class efficiency IE3, 2 poles, 900 kW, CENELEC

PN: 3GBP451520-••K

Motor type
M3BP 450LB 2
Output (kW)
900
Poles
2
Efficiency class according to IEC 60034-30-1; 2014
IE3
IEC size (shaft height)
450
Frame material
cast iron
Enclosure
IP55
Design
CENELEC
Insulation class
F
Cooling Method
IC 411
Voltage Un
400V 50Hz
Speed (r/min) Un=400V 50Hz
2990
Efficiency IEC 60034-30-1: 2014 Full load 100% Un=400V 50Hz
95,8
Efficiency IEC 60034-30-1: 2014 >3/4 load 75% Un=400V 50Hz
95,5
Weight (kg)
4200
Efficiency IEC 60034-30-1: 2014 1/2 load 50% Un=400V 50Hz
94,7
Power factor Cos φ Un=400V 50Hz
0,87
Current In (A) Un=400V 50Hz
1534
Current Is/In Un=400V 50Hz
7,6
Torque TN (Nm) Un=400V 50Hz
2874
Torque TI/TN Un=400V 50Hz
1,5
Torque Tb/TN Un=400V 50Hz
3,1
Moment of inertia J = 1/4 GD2kgm2
13,5
Sound pressure Level LPA (dB) Un=400V 50Hz
85
Temperature rise class Un=400V 50Hz
B
Remark Un=400V 50Hz
2) 3)
Voltage Un
460V 60Hz
Speed (r/min) Un=460V 60Hz
3591
Efficiency IEC 60034-30-1: 2014 Full load 100% Un=460V 60Hz
95,8
Efficiency IEC 60034-30-1: 2014 >3/4 load 75% Un=460V 60Hz
95,5
Efficiency IEC 60034-30-1: 2014 1/2 load 50% Un=460V 60Hz
94,6
Power factor Cos φ Un=460V 60Hz
0,85
Current In (A) Un=460V 60Hz
1366
Current Is/In Un=460V 60Hz
7,8
Torque TN (Nm) Un=460V 60Hz
2393
Torque TI/TN Un=460V 60Hz
1,5
Torque Tb/TN Un=460V 60Hz
3,4
Moment of inertia J = 1/4 GD2kgm2 Un=460V 60Hz
13,5
Sound pressure Level LPA (dB) Un=460V 60Hz
90
Temperature rise class Un=460V 60Hz
B
Remark Un=460V 60Hz
2) 3)