Motor type

Motor size

Product code

Mounting arrangement code,
Voltage and frequency code,
Generation code

Variant codes


M2BAX

Position

112MA

3GBA 112 310 - 

 1  2  3  4     5 6 7    8 910 11 

ADD

12 13 14

+002, etc.


Positions 1 to 4
3GBA               Totally enclosed fan cooled squirrel cage motor
                         with cast iron frame


Positions 5 and 6
IEC size                                           IEC size
07: 71                                               18: 180 
08: 80                                               20: 200
09: 90                                               22: 225
10: 100                                             25: 250
11: 112                                             28: 280
13: 132                                             31: 315 
16: 160                                             35: 355                                       



Position 7
Speed (Pole pairs)
1: 2 poles
2: 4 poles
3: 6 poles


Positions 8 to 10
Serial number


Position 11
- (dash)


Position 12 (marked with black dot in data tables)
Mounting arrangement
A: Foot-mounted, top-mounted terminal box
B: Flange-mounted, large flange


Position 13 (marked with black dot in data tables)
Voltage and frequency
Single-speed motors
D: 400 VΔ, 415 VΔ, 690 VY 50 Hz
S: 230 VΔ, 400 VY, 415 VY 50 Hz


Position 14
Generation code
A, B, C...Generation code followed by variant codes.

Variant codes M2BAX



Output (kW)
Poles
Efficiency class according to IEC 60034-30-1; 2014
IEC size (shaft height)