ABB Drives Low voltage motors IEC M3AA - Process performance aluminum motors

M3AA - Process performance aluminum motors



Motor type

Motor size

Product code

Mounting arrangement code,
Voltage and frequency code,
Generation code

Variant codes


M3AA

Position

112MB

3GAA 111 320 - 

1   2  3  4     5 6 7    8 910 11 

ADK

12 13 14

+003, etc.


Positions 1 to 4
3GAA               Totally enclosed motor with aluminum stator frame


Positions 5 and 6
IEC size                                           IEC size
05: 56                                              13: 132 
06: 63                                              16: 160 
07: 71                                              18: 180 
08: 80                                              20: 200
09: 90                                              22: 225
10: 100                                            25: 250
11: 112                                            28: 280*
                                           


Position 7
Speed (Pole pairs)
1: 2 poles
2: 4 poles
3: 6 poles
4*: 8 poles
5*: 10 poles
6*: 12 poles
7*: > 12 poles

Positions 8 to 10
Serial number


Position 11
- (dash)


Position 12 (marked with black dot in data tables)
Mounting arrangement
A: Foot-mounted motor
B: Flange-mounted motor. Large flange with clearance holes
C: Flange-mounted motor. Small flange with tapped holes
F:* Foot- and flange-mounted. Special flange
H: Foot- and flange-mounted motor. Large flange with clearance holes
J: Foot- and flange-mounted motor. Small flange with tapped holes
N:* Flange-mounted (CI ring flange FF)
P:* Foot-and flange-mounted motor (CI ring flange FF)
V:* Flange-mounted motor. Special flange

Position 13 (marked with black dot in data tables)
Voltage and frequency
Single-speed motors
B:* 380 VΔ 50 Hz
D: 400 VΔ, 415 VΔ, 690 VY 50 Hz
E:* 500 VΔ 50 Hz
F:* 500 VY 50 Hz
S: 230 VΔ, 400 VY, 415 VY 50 Hz
T:* 660 VΔ 50 Hz
U:* 690 VΔ 50 Hz
X:* Other rated voltage, connection or frequency, 690 V maximum


Position 14
Generation code
A, B, C.......: Generation code followed by variant codes.

VARIANT CODES M3AA



* Not as standard offering, can be ordered as customer-specific solution.



Output (kW)
Poles
Efficiency class according to IEC 60034-30-1; 2014
IEC size (shaft height)