DCS tank systems were specially developed for filtering separators with pressure impulse cleaning. Systems with different dimensions are available for customized configuration (for your configuration please contact us). The purge gas tank systems meet the requirements of the Pressure Equipment Directive 2014/68 / EU and other international approvals. The RECO production of pressure equipment is monitored by the notified body DEKRA 2266 and is valid for module A2.


 

ST140/120-DN 40 VS

Purge gas tank system with integrated diaphragm valve, pilot operated.

Aluminium purge gas tank system according to pressure equipment directive 2014/68/EU
with DN-25 pilot operation
Design for through valves with variable valve spacing
Very high pressure pulse through straight valve guide
TPE-E Power Reflex diaphragm with very short pressure rise and reflecting closing function
Filter controllers or valve boxes can be directly attached to the aluminium section
5000 mm maximum length of the aluminium section






ST148-DN 20 / -DN 25 VR

Purge gas tank system with 90° angle diaphragm valves VR-DN 20

Aluminium purge gas tank system according to pressure equipment directive 2014/68/EU
Design for screwed on VR valves with variable distances on one side or both sides
High pressure pulse thanks to flow-optimized design of the VR valves
TPE-E Power Reflex diaphragm with very short pressure rise and reflecting closing function
Filter controllers or valve boxes can be directly attached to the aluminium section
Various connection options and accessories for tank filters and valve outlet purge lance
5000 mm maximum length of the aluminium section





ST148-DN 20 SD / -DN 25 SD

Purge gas tank system with integrated diaphragm valve SD (small distance), min. 55 mm valve spacing

Aluminium purge gas tank system according to pressure equipment directive 2014/68/EU
Design for through valves with variable valve spacing
through staggered valve arrangement allows small distances (SD) especially for pocket filters
Very high pressure pulse through straight valve guide
TPE-E Power Reflex diaphragm with very short pressure rise and reflecting closing function
Filter controllers or valve boxes can be directly attached to the aluminium section
4000 mm maximum length of the aluminium section





ST148-DN 20 / -DN 25

Purge gas tank system standard design with integrated diaphragm valve, min. 75 mm valve spacing

Aluminium purge gas tank system according to pressure equipment directive 2014/68/EU
Design for through valves with variable valve spacing
Very high pressure pulse through straight valve guide
TPE-E Power Reflex diaphragm with very short pressure rise and reflecting closing function
Filter controllers or valve boxes can be directly attached to the aluminium section
5000 mm maximum length of the aluminium section





ST160-DN 25 / -DN 40 VS / -DN 50 VS

Purge gas tank system with integrated diaphragm valve, DN 25 directly operated / DN 40 and DN 50 pilot operated

the new ST-160 profile is ASME-compliant, Di < 150 mm
one aluminium section for all valve sizes DN 25 – DN 40 VS – DN 50 VS
different valve sizes are possible in one purge gas tank
Aluminium purge gas tank system according to pressure equipment directive 2014/68/E
very high pressure impulse by direct mounting of the valves in the aluminium section
TPE-E Power Reflex diaphragm with very short pressure rise and reflecting closing function
Filter controllers or valve boxes can be directly attached to the aluminium section
5000 mm maximum length of the aluminium section
Volume increase by flanged second tank – also ASME-compilant





ST160-DN 40 VR

Purge gas tank system with 90° angle diaphragm valves VR-DN 40

the new ST-160 profile is ASME-compliant, D < 150mm
Aluminium purge gas tank system according to pressure equipment directive 2014/68/E
Design for screwed on VR valves with variable distances on one side or both sides
High pressure pulse thanks to flow-optimized design of the VR valves
TPE-E Power Reflex diaphragm with very short pressure rise and reflecting closing function
Filter controllers or valve boxes can be directly attached to the aluminium section
Various connection options and accessories for tank filters and valve outlet purge lance
5000 mm maximum length of the aluminium section





ST172-DN 40 VS

Purge gas tank system with integrated diaphragm valve, pilot operated

Aluminium purge gas tank system according to pressure equipment directive 2014/68/EU
with DN-25 pilot operation
Design for through valves with variable valve spacing
Very high pressure pulse through straight valve guide
TPE-E Power Reflex diaphragm with very short pressure rise and reflecting closing function
Filter controllers or valve boxes can be directly attached to the aluminium section
4000 mm maximum length of the aluminium section





ST172-DN 50 VS

Purge gas tank system with integrated diaphragm valve, pilot operated

Aluminium purge gas tank system according to pressure equipment directive 2014/68/EU
with DN-25 pilot operation
Design for through valves with variable valve spacing
Very high pressure pulse through straight valve guide
TPE-E Power Reflex diaphragm with very short pressure rise and reflecting closing function
Filter controllers or valve boxes can be directly attached to the aluminium section
4000 mm maximum length of the aluminium section