The PICO XP jetting system takes the guesswork out of how to achieve the same extremely precise (XP), repeatable non-contact micro-dispensing from valve-to-valve, after maintenance, and as temperatures rise or fall.
The PICOPµlse®XP jet valve and PICO®Toµch™XP controller bring extreme precision and repeatability to the next level with a unique self-regulating calibration for improved valve-to-valve jetting performance.
It controls for the slightest variation in fluid body tolerances to maintain optimal jetting results, even after maintenance. Sustained stroke target seeking allows the system to produce a stable deposit weight,even when environmental conditions change.
This minimizes production downtime needed to recalibrate the jetting system, for example, when ambient temperatures rise or fall.
Achieve micro-deposits as small as 0.5 nL with extreme precision and repeatability at up to 1000Hz continuous for your most sophisticated non-contact dispensing application needs.
Features
• XP self-regulating calibration.
• Sustained stroke target seeking
• Micron (µm) level stroke adjustment
• Touchscreen interface with intuitive programming software
• Tool-free fluid body removal for simplified cleaningof fluid path
Benefits
• Improve valve-to-valve dispensing repeatability and repeatability after maintenance
• Maintain dispensing repeatability regardless of environmental conditions
• Fine-tune jetting performance for a wide rangeof applications
Item Product
Cabinet size: 14.2W x 13.3H x 16.8D cm (28 Hp x 3U) (5.6W x 5.25H x 6.6D")
Weight: 2.6 kg (5.5 lb)
Input: AC (to power supply) 100–240 VAC +/-10%, 50–60 Hz, 2A
Output: DC (from power supply) 24 V, 6.25 A
Internal voltage: 150 VDC, 24 VDC, 5 VDC, and 3.3 VDC
Heater output voltage 24 VDC, 30 W maximum
Feedback circuit: 0–24 VDC
Initiate circuit: 5–24 VDC
Heater outputs: Setpoint range: 0–100° C (32–212° F); 0.1° C increments, Temperature input type at valve: RTD, Indication accuracy: ±1° C, Sample rate: 60 per second, Control method: PID
Cycle rate: Valve-dependent
Time range: 100 μs to 9.9999 s (depending on the open profile time)
Ambient operating conditions: Temperature: 5–45° C (41–133° F), Humidity: 85% relative humidity at 30° C (86° F), non-condensing, Height above sea level: 2000 m (6,562 ft) maximum, Indoor use only
Product classification: Installation category II, Pollution degree 2
Approvals: CE, RoHS, WEEE, and China ROHS compliant